Hyundai Accent: Purge Control Solenoid
Valve (PCSV). Description and Operation
Description
Purge Control Solenoid Valve (PCSV) is installed on the surge
tank and controls the passage between the canister and the intake manifold.
It is a solenoid valve and is open when the ECM grounds the valve control line.
When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred
to the intake manifold.

The injector combustion seal should be replaced new one to
prevent leakage after removing the injector.
1.
Remove the combustion seal (A) with a wire cutter.
...
Specification
Item
Specification
Coil Resistance (Ω)
22.0 ~ 26.0 [20°C(68°F)]
...
See also:
Anchor Pretensioner (APT). Description and Operation
Description
Front anchor pretensioner operates as well as Belt Pretensioner at the
same time If it gets into its deploy condition after a collision. It is located
at near anchor on driver se ...
Description
Body control module (A) receives various input switch signals controlling
time and alarm functions for the door lock/unlock control, lamp control,
power window timer warning con ...
Circuit Diagram - ESC (1)
...