1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the CCV connector.
|
3. |
Measure resistance between the CCV terminal 1 and
2.
|
4. |
Check that the resistance is within the specification.
|
5. |
Disconnect the vapor hose connected with the canister
from the CCV.
|
6. |
Connect a vacuum pump to the nipple.
|
7. |
Ground the CCV control line and apply battery voltage
to the CCV power supply line.
|
8. |
Apply vacuum and check the valve operation.
|
Installation
•
Do not turn the ignition switch ON and do not contact
the battery cable while replacing the ...
Back-up Lamp Switch. Specifications
Specifications
1.
Working voltage: DC 10~15V
2.
Operating force: 3.0kg Max.
3.
Voltage drop: - 0.4V
...
Variable Intake Solenoid
(VIS) Valve. Specifications
Specification
Item
Specification
Coil resistance (Ω)
30.0 ~ 35.0 [20°C(68°F)]
...