Hyundai Accent Manuals

Hyundai Accent: 26 Brake Control Solenoid Valve(26/B_VFS). Specifications - Automatic Transaxle Control System - Automatic Transaxle SystemHyundai Accent: 26 Brake Control Solenoid Valve(26/B_VFS). Specifications

Specifications

Direct control VFS[26/B]
▷ Control type : Normal low type
Control Pressure kpa (kgf/cm², psi)
9.81 ~ 500.14
(0.1 ~ 5.5, 1.42 ~ 7.82)
Current value(mA)
50 ~ 850
 Internal resistance(Ω)
5.1


26 Brake Control Solenoid Valve(26/B_VFS). Description and Operation
Description 26 brake control solenoid valve(26/B_VFS) is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the 26 brake. ...

26 Brake Control Solenoid Valve(26/B_VFS). Schematic Diagrams
Circuit Diagram ...

See also:

Installation
1. Install the high mounted stop lamp. 2. Install the trunk trim. ...

Overdrive Clutch Control Solenoid Valve(OD/C_VFS). Specifications
Specifications Direct control VFS[OD/B] ▷ Control type : Normal high type Control Pressure kpa (kgf/cm², psi) 500.14 ~ 9.81 (5.5 ~ 0.1, 7.82 ~ 1.42) ...

Replacement
Standard values, such as torques and certain adjustments, must be strictly observed in the reassembly of all parts. If removed, the following parts should always be replaced with new ones ...