Hyundai Accent: Purge Control Solenoid
Valve (PCSV). Description and Operation
Description
Purge Control Solenoid Valve (PCSV) is installed on the surge
tank and controls the passage between the canister and the intake manifold.
It is a solenoid valve and is open when the ECM grounds the valve control line.
When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred
to the intake manifold.

The injector combustion seal should be replaced new one to
prevent leakage after removing the injector.
1.
Remove the combustion seal (A) with a wire cutter.
...
Specification
Item
Specification
Coil Resistance (Ω)
22.0 ~ 26.0 [20°C(68°F)]
...
See also:
Inspection
1.
Inspect diaphragm spring wear which is in contact
with a concentric slave cylinder bearing.
2.
Check the clutch cover and disc surface f ...
Automatic heating and air conditioning
1. Press the AUTO button.
The modes, fan speeds, air intake and air-conditioning will be controlled automatically
according to the temperature setting.
2. Turn the temperature control knob to ...
Circuit Diagram - ESC (4)
...