Inspection
1. |
Disconnect the vapor hose from the intake manifold
and connect a vacuum pump to the nipple on the intake manifold.
· At Cold Engine [Engine Coolant Temperature < 60°C(140°F)]
|
2. |
Check the following points with applied vacuum at
the purge control solenoid valve (PCSV).
· At Warmed Engine [Engine Coolant Temperature. 80°C(176°F)]
|
1. |
Turn ignition switch OFF and disconnect the negative
(-) battery cable.
|
2. |
Disconnect the PCSV connector (A).
|
3. |
Disconnect the vapor hose (B) which is connected
to the intake manifold from the PCSV.
|
4. |
After connecting a vacuum pump to the nipple, apply
vacuum.
|
5. |
With the PCSV control line grounded, check the valve
operation with battery voltage applied to the PCSV(Open) and removed(Closed).
|
6. |
Measure the coil resistance of the PCSV.
|
1. |
Select "Evap. Leakage Test".
|
2. |
Proceed with the test according to the screen introductions.
|
Instrument Cluster. Components
and Components Location
Components
...
Installation
1.
Installation is the reverse of removal.
•
...
Actual Measurement Dimensions ( 4Door )
Front side member tooling hole (Ø6.6)
Side cover mounting hole
(B/B’: Ø6.6/ Ø8.6)
...