Inspection
1. |
Disconnect the vapor hose from the intake manifold
and connect a vacuum pump to the nipple on the intake manifold.
· At Cold Engine [Engine Coolant Temperature < 60°C(140°F)]
|
2. |
Check the following points with applied vacuum at
the purge control solenoid valve (PCSV).
· At Warmed Engine [Engine Coolant Temperature. 80°C(176°F)]
|
1. |
Turn ignition switch OFF and disconnect the negative
(-) battery cable.
|
2. |
Disconnect the PCSV connector (A).
|
3. |
Disconnect the vapor hose (B) which is connected
to the intake manifold from the PCSV.
|
4. |
After connecting a vacuum pump to the nipple, apply
vacuum.
|
5. |
With the PCSV control line grounded, check the valve
operation with battery voltage applied to the PCSV(Open) and removed(Closed).
|
6. |
Measure the coil resistance of the PCSV.
|
1. |
Select "Evap. Leakage Test".
|
2. |
Proceed with the test according to the screen introductions.
|
Inspection
1.
Check the bushing for wear and deterioration.
2.
Check the front stabilizer bar for deformation.
3.
Check th ...
Exterior care
Exterior general caution
It is very important to follow the label directions when using any chemical cleaner
or polish. Read all warning and caution statements that appear on the label.
Finish mai ...
Installation
1.
Install the BCM.
2.
Install the crash pad lower panel.
...