Inspection
1. |
Disconnect the vapor hose from the intake manifold
and connect a vacuum pump to the nipple on the intake manifold.
· At Cold Engine [Engine Coolant Temperature < 60°C(140°F)]
|
2. |
Check the following points with applied vacuum at
the purge control solenoid valve (PCSV).
· At Warmed Engine [Engine Coolant Temperature. 80°C(176°F)]
|
1. |
Turn ignition switch OFF and disconnect the negative
(-) battery cable.
|
2. |
Disconnect the PCSV connector (A).
|
3. |
Disconnect the vapor hose (B) which is connected
to the intake manifold from the PCSV.
|
4. |
After connecting a vacuum pump to the nipple, apply
vacuum.
|
5. |
With the PCSV control line grounded, check the valve
operation with battery voltage applied to the PCSV(Open) and removed(Closed).
|
6. |
Measure the coil resistance of the PCSV.
|
1. |
Select "Evap. Leakage Test".
|
2. |
Proceed with the test according to the screen introductions.
|
Removal
1.
Disconnect the battery negative cable and wait for at least three
minutes before beginning work.
2.
Turn the steering wheel so that the ...
Crash Pad. Repair procedures
Replacement
Cluster Replacement
•
When prying with a flat-tip screwdriver, wrap it with
...
Back-up Lamp Switch. Specifications
Specifications
1.
Working voltage: DC 10~15V
2.
Operating force: 3.0kg Max.
3.
Voltage drop: - 0.4V
...