Hyundai Accent: General| 1. |
Basically, all measurements in this manual are taken with a tracking
gauge.
|
| 2. |
When a measuring tape is used, check to be sure there is no elongation,
twisting or bending.
|
| 3. |
For measuring dimensions, both projected dimension and actual-measurement
dimension are used in this manual.
|
Measurement MethodSS-A Solenoid Valve(ON/OFF). Specifications
Specifications
ON/OFF Solenoid Valve(SS-A, SS-B)
▷ Control type : Normal low type
Control pressure kpa (kgf/cm², psi)
490.33(5.0, 71.12)
...
Torque Converter Control Solenoid Valve (T/CON_VFS). Schematic Diagrams
Circuit Diagram
...
Removal
1.
Remove the following items;
A.
Engine cover (A).
B.
Air cleaner assembly and air duct (B).
...